Adtec-digital EN-91 / EN-91P (version 1.02.29) Quick Start Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Vidéo Adtec-digital EN-91 / EN-91P (version 1.02.29) Quick Start. Adtec digital EN-91 / EN-91P (version 1.02.29) Quick Start User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Thank you for your purchase of the Adtec
EN-91 Encoder. This product is sold with optional
modulator hardware packages. Configurations and
indicators relevant to those add-on packages are
noted here. If you purchased this product without a
modulator, please ignore settings noted with an
asterisks (*).
The most recent firmware releases are available
on our support website, www.adtecdigital.com.
Advanced users can find direct API command help
as part of the on-board web application, Help Tab.
Adtec Digital US Sales +1-615-256-6619 International Sales +1-904-394-0389 www.adtecdigital.com 2013 Adtec Digital
Front Panel Menus:
Use Mode Button to move
through top layer menus.
Use arrows for navigation
in submenus.
Use select to enter into edit
mode and enter to save
selection.
SELECT
ENTER
MODE
Reset:
Should you need to
reset your device, you
can do so via the front
panel by pressing the
MODE, ESCAPE and
RIGHT ARROW keys
simultaneously.
Units ship with the front panel logged in
by default. If you become logged out and
are prompted for a password, use the
following key sequence for access.
Press <Select> when panel displays
‘User Login -- logged out’
Press <Up arrow>
Press <Select>
Press <Enter>
Press <Right arrow>
Press <Enter>
MPEG4 DSNG Encoder / Modulator
91 or EN91P
Model Indicators:
L-Band modulator
IF modulator
No modulator
Alarm
Off - No system alarms
On - System alarm
BISS
Off - No encryption set
On - Encryption active
Busy
Off - No network activity
On - Network traffic present
Link
Off - No network detected
On - Network communication active
System LED Status
Encoder LED Status
Video
Off - If modulator is installed, no video is
detected or ASI Receive mode is enabled.
On - Video is detected.
Blink - No video is detected and fault mode
is active.
Encode
Off - Device is not encoding. Idle State
On - Device is encoding.
VAF
Off - Video autofill is off.
On - Video autofill is on.
4:2:2
Off - Encoding chroma type 4:2:0.
On - Encoding chroma type 4:2:2.
HD
Off - Encoding standard definition.
On - Encoding high definition.
IP Out
Off - Transport of IP via Ethernet or
GigE is idle.
On - Transport of IP via Ethernet or
GigE is active.
GOOD 20.000M ASI 00001 AdtecDigital
1920x1080 29i AC MU MU MU -- -- -- -
SELECT
1
2abc
3def
5jkl
6mno
7pqrs
8tuv
9wxyz
0
4ghi
F1
F2
ENTER
ESCAPE
MODE
HD
IP Out
RF Out
Bars
91
MPEG 4
DSNG Encoder
VAF
A5
A6
A7
A8
ENCODING:20.000M ! FAULT MODE! CAS:OFF
SVC: 00001 “Service Name Service Provider
Quick View Status
Audio 1:11300 3:11400 5:11500 7:11600
PIDS 2:11300 4:11400 6:11500 8:11600
Audio PIDS 1- 8
For information on the core systems, use the down
arrorw on the front panel to scroll through these
quick view menus.
Encoder Activity TMR Fault Mode Status Encryption
Service ID Service Name Service Provider
ENCODING:20.000M !FAULT MODE! CAS:OFF
SVC: 00001 “Service Name Service Provider
Quick Start Guide
Input: Resolution Frame Rate Source
Output: Resolution Frame Rate Bars Status
I/ RES: 1920X1080 59i INP: SDI
O/RES: 1920X1080 59i B/T/ID:OFF/OFF/OFF/OFF
1:MU 384k 3:MU 384k 5:MU 384k 7:MU 384k
2:MU 384k 4:MU 384k 6:MU 384k 8:MU 384k
Audio Status
Video PID PCR PID Codec Chroma
Video Rate Entropy Mode Auto Fill
VID: 481 PCR:481 COD:H.264 CHR:420
VRT:60000000b/s ENT:CABAC A/F:OFF
IP status RTP FEC Connector Transports 1 - 4
1: SEND ON BUR GIGE 3: OFF OFF OFF GIGE
2: OFF OFF OFF GIGE 4: OFF OFF OFF GIGE
TX:Enabled 32APSK_9/10 Pwr:-30dB RO:25%
Freq:1291MHz DVB-S2 Sym:15.00Ms Pilot:On
Modulator Status Mod FEC Power RollO
Frequency Mode Symbol Rate Pilot
* RF Out
Off - Modulator is not transmitting.
On - Modulator is transmitting.
Blink - Modulator is in test mode.
Bars
Off - B/T/ID options are disabled.
On - B/T/ID are enabled.
A1 - A8
Off - Audio encoder cfg. is off.
On - Audio encoder cfg. is set to
encode or passthru.
Use the F2 button as a decimal.
F2
Special Keys:
Press the F1 and F2
buttons
simultaneously
to jump
to Modulator Line-up Mode.
**Detail on reverse.
F1
F2
Services
TS Mux Rate
Program Number
ABR Mode
Service Name
Service Provider
Tables
Splice PID Active
ASI Receive Mode
ASI Mode
Carrier ID Menu
Bars, Tones, ID Menu
* RF Tx
Transmit
Type
Mode
Frequency (MHz)
Power (dBm)
Spectrum Inversion
Fec Frame
Roll O
Pilot
Rate Priority
Symbol Rate
Interface Rate
Carrier Mode
10 MHz Clock
10 MHz Clock Comb.
IPTx
<< 1 - 4 >>
Mode
Tx IP Address
Tx Port
DVB per IP
RTP
FEC Mode
FEC L
FEC D
TOS
TTL
Tx Connector
Video
Input
SDI Mode
Entropy Coding
Chroma
Video Rate (b/s)
Autoll
Latency
Latency Trim
Fault Mode
Fault Resolution
Aspect Ratio
AFD
GOP Type
GOP Structure
GOP Size
SD Video Mode
3D-Sync Mode
Audio
Sampling Frequency
SDI Clock Source
ECC Words
Level B * 91P only
<< 1 -8 >>
Input
Mode
Type
Rate
Level
Analog Aud. Level
(1-2 Only)
Sync
Musicam Mode
IFB
SDI Pair
PIDs
Transport Stream ID
PMT PID
PCR PID
Video PID
Audio 1 PID
Audio 2 PID
Audio 3 PID
Audio 4 PID
Audio 5 PID
Audio 6 PID
Audio 7 PID
Audio 8 PID
Teletext PID
VITC PID
AMOL PID
Splice PID
VBI
Source
Closed Caption
VITC Menu
Prole
Select
Save
Delete
CAS
Mode
Clear Session Word
Encrypt Session Word
User ID 1
User ID 2
System
Login
Duration
Backlight Dim Delay
Network Menu
Time Menu
NTP Menu
Alarm
SNMP Menu
COM 2
Feature Menu
Name
Firmware Version